Comparative behaviour of devices DRGB-01 “ECO-1”, DRGB-01 “ECO-1М” and ECO-1M with external detector.
|
|
DRGB-01 |
ECO-1M with external detector |
|
gamma, beta | ||
Photon energy range, MeV | 0,015…3,0 | ||
Energy range of beta particles, MeV | More than 0,15 | ||
Measurement range EDR, mkSv/h | 0,10…1000 | ||
Measurement range ED, mkSv | - | 0,10…100000 | |
Measurement range of flux density of beta particles, 1/(s×cm2) |
0,1…100 | 0,1…700 | |
The level of measurement of ambient activity Сs-137, Sr-90 , kBk/kg |
4,0…100 in probe by flux from |
- | - |
The mode of operation | 5 fix modes | menu | |
The threshold of alarm, mkSv/h | 0,6 | 0,30; 0,60; 2,0 | |
The coefficient of variation, % | no | no more than 2, 5, 10, 20 | |
The display indication | digital | digital, analog, graphical | |
The time of measurement, sec |
gamma- mode F - 20 mode A - 800 beta- mode B - 160 |
gamma- 2, 10, 20, 60 beta- no more than 100 |
|
The temperatureof operation, °С |
-20…+50 |
-20…+50 (device) -40…+50 (external detector) |